Balometer used to measure CFM at supply and return ducts. Helps to evaluate duct leakage, system operation, etc.
|
|
|
|
Solomat IAQ Surveyor Pro measures parameters including temp., %RH, CO, CO2, Building Pressure, Differential Pressure, Air Velocity at Ducts and more
|
|
|
|
Tramex Survey Encounter used to measure temperature and moisture of materials and datalog results
|
|
|
|
Gastec Colormetric Sampling Pump used to measure specific indoor chemical concentrations
|
|
|
|
A-6 Bioaerosol Sampler used for taking viable samples onto selective media (agar plates)
|
|
|
|
|
Photovac 2020 Photoionization Air Monitor used to measure TVOC's (non-specific)
|
|
|
|
Drager Accuro used for colormetric tube tomeasure specific contaminants in air
|
|
|
|
Raytek Laser Non-Nontact thermometer used to measure surface temperature, look for building leakge, assess R values, find dew-point problems
|
|
|
|
BIOS DryCal (DC Lite) used to calibrate air sampling pumps in the field
|
|
|
|
Infrared Thermal Imaging camera used during building energy audits, moisture damage assessment, construction defect investigations and roof assessment
|
|
|
|
|
Moisture meter used to assess inside wall moisture, EIFS, etc.
|
|
|
|
Blower Door used during energy survey's and pressure diagnostics
|
|
|
|
Pipe camera system used for evaluation of underground piping and ducts.
|
|
|
|
Duct Blaster used to measure total system airflow and duct leakage.
|
|
|
|
Low E, Solar Gain meter used to evaluate proper window installations
|
|
|
|
|
Moisture Detection Meters for concrete, flat roofs, EIFS, wood, general purpose, data-logging
|
|
|
|
Provision Borescope used for eval;uating inside wall cavities, heat exchangers, etc.
|
|
|
|
Protimeter Moisture Measurement System (MMS) used for measuring dew-points, moisture, humidity, slab moisture, etc.
|
|
|
|
TrueFlow airflow measurement. Used for measuring total airflow at air handler.
|
|
|
|
TelAire CO2 Monitors used with HOBO Dataloggers, HOBO CO Monitors, HOBO Outdoor Monitor used for logging building parameters during IAQ assessments.
|
|
|
|
|
Lighthouse 3016 Particle Counter. This IAQ mdel measures particulate from 0.3 to 10 µm
|
|
|
|
Fyritr Pro combustion analyzer used for assessing fossil fueled appliances
|
|
|
|
Summa can used for taking grab or 8 hr. VOC air samples for analysis
|
|
|
|
Pressure pans. Used for performing preliminary duct leakage analysis.
|
|
|
|
C.L.I. designed IAQ investigation cart.
|
|
|
|
|
ppbRAE is the most sensitive pid on the market today. Used in IAQ investigations, odor assessment, drug lab evaluations
|
|
|
|
Humilog used for condensation monitoring, drying monitoring, moisture investigations
|
|
|
|
Fluke IR-Fusion Technology Infrared Camera. Allows for accurate IR assessments of roofs, energy loss, electrical systems, moisture, etc.
|
|
|